HBCP NH3 Compressor protection

HBCP is a new revolutionary, patent-pending sensor technology and it is the first sensor in the world capable of measuring the condition of gas and liquid refrigerant in a refrigeration system. HBCP is used for detecting gas quality at the intake found on refrigeration compressors. The sensors thereby ensure that liquid refrigerant does not enter the compressor, causing damage to the moving parts.

The sensor has a high sensitivity and even detects small liquid droplets before they become critical to the compressor. The sensor has a uniquely low reaction time, and thereby ensures that the compressor is not damaged. In the event of liquid hammer, an instantaneous alarm is sent to the compressor control, which must signal an emergency stop to the compressor. The sensor measures the total gas and liquid capacity, which is displayed in pF.

 

Product features:

The sensor protects the compressor against damage in the event of liquid hammer from the system.
Setting up the sensor using a PC allows for adjustments to match the system and the compressor.
Instantaneous reaction without delays.

 

 


Power supply
Voltage 24 V DC + 10%
Power usage Max 30 mA
Plug connection M12, 5 pins
Output
Transsistor PNP NO or NC (programmable)
Alarm indication for gas/liquid condition Warning / Alarm
Environmental conditions
Ambient temperature -30°C…+50°C
Refrigerant temperature -60°C…+80°C
Max. pressure 100 bar
Waterproof rating IP65
Vibrations IEC 68-2-6 (4g) 
Mechanical specifications
Thread connection 3/4” NPT and 1″ BSPP 
Material of the parts coming into contact with liquid AISI 304
Material of the electronic parts GF BLK, Nylon 6 (PA)
Output See drawing
Type  Front housing 
Approvals
EMC test EN 61000-2
Cable
5m cable with M12 plug  HBxC-M12/5 
Cable specifications  PUR -5 x 0,34mm2 
Indication
LED Indication LED (green, yellow, and red)
Configurations
Configuration With the PC tool

Power supply
Voltage 24 V DC + 10%
Power usage Max 30 mA
Plug connection M12, 5 pins
Output
Transsistor PNP NO or NC (programmable)
Alarm indication for gas/liquid condition Warning / Alarm
Environmental conditions
Ambient temperature -30°C…+50°C
Refrigerant temperature -60°C…+80°C
Max. pressure 100 bar
Waterproof rating IP65
Vibrations IEC 68-2-6 (4g) 
Mechanical specifications
Thread connection 3/4” NPT and 1″ BSPP 
Material of the parts coming into contact with liquid AISI 304
Material of the electronic parts GF BLK, Nylon 6 (PA)
Output See drawing
Type  Front housing 
Approvals
EMC test EN 61000-2
Cable
5m cable with M12 plug  HBxC-M12/5 
Cable specifications  PUR -5 x 0,34mm2 
Indication
LED Indication LED (green, yellow, and red)
Configurations
Configuration With the PC tool

Power supply
Voltage 24 V DC + 10%
Power usage Max 30 mA
Plug connection M12, 5 pins
Output
Transsistor PNP NO or NC (programmable)
Alarm indication for gas/liquid condition Warning / Alarm
Environmental conditions
Ambient temperature -30°C…+50°C
Refrigerant temperature -60°C…+80°C
Max. pressure 100 bar
Waterproof rating IP65
Vibrations IEC 68-2-6 (4g) 
Mechanical specifications
Thread connection 3/4” NPT and 1″ BSPP 
Material of the parts coming into contact with liquid AISI 304
Material of the electronic parts GF BLK, Nylon 6 (PA)
Output See drawing
Type  Front housing 
Approvals
EMC test EN 61000-2
Cable
5m cable with M12 plug  HBxC-M12/5 
Cable specifications  PUR -5 x 0,34mm2 
Indication
LED Indication LED (green, yellow, and red)
Configurations
Configuration With the PC tool

Inquiry

Niezwłocznie po wpłynięciu do nas zapytania zostanie przygotowana dla Państwa oferta wraz ze szczegółową wyceną.