Parker-Herl T5VA.F T5VA.F.L Globe Shut-Off Valve DN15 - DN200 (1/2“ to 8“)
Valves with cap or hand wheel. Valves with back seating: Packing can be repacked under pressure. Hydraulic pressure test with PS x 1.43 -medium water, tightness test with PS -medium air. Depending on the application range different equipment is required.
- Suitable for refrigerants acc. to: EN 378-1 (annex E). Brines on request.
- Medium temperature -60°C to +160°C
- Design: DIN EN 12284, EN 378
- Length: DN 15-32 HERL-Standard, DN 40-200 DIN EN 12982
- Connections: butt welding ends acc. to DIN EN 12627 or ASMEANSI B16.25 Schedule 40, 80
- Conformity to Pressure Equipment Directive 2014/68/EU
- Suitable for refrigerants acc. to: EN 378-1 (annex E). Brines on request.
- Medium temperature -60°C to +160°C
- Design: DIN EN 12284, EN 378
- Length: DN 15-32 HERL-Standard, DN 40-200 DIN EN 12982
- Connections: butt welding ends acc. to DIN EN 12627 or ASMEANSI B16.25 Schedule 40, 80
- Conformity to Pressure Equipment Directive 2014/68/EU
Inquiry