HBLT-A1 NH3 Refrigerant Level Sensor (AKS41)
HBLT capacitive liquid level transmitters are used to measure liquid levels in refrigerant vessels.
The HBLT transmits an active 4-20 mA signal which is proportional to the liquid level.
4 mA when the transmitter does not register liquid and 20 mA when the entire transmitter is surrounded by liquid
The 4-20 mA signal from HBLT can be used in conjunction with a controller e.g HBLT-C1 to control the liquid level.
The HBLT transmits an active 4-20 mA signal which is proportional to the liquid level. 4 mA when the transmitter does not register liquid and 20 mA when the entire transmitter is surrounded by liquid. The 4-20 mA signal from HBLT can be used in conjunction with a controller e.g HBLT-C1 to control the liquid level.
![]() |
Proven and reliable design with process signal output of 4-20 mA. |
![]() |
Split design makes it easy install and make diagnostic. The electronic parts can be easily disconnected with 2 small screws. |
![]() |
Simple calibration function and the possibility to reduce the effect of liquid peaks. |
![]() |
Designed for the industrial refrigeration industry – max pressure up to 100 bar & high protection degree. |
| Power supply | |
|---|---|
| Voltage | 24 AC/DC + 10% |
| Max. possible resistance | 500 ohm |
| Plug connection | DIN 43650 – 4 pins |
| Output | |
| Analog output | 4-20 mA |
| Environmental conditions | |
| Ambient temperature | -30…+50°C |
| Refrigerant temperature | -60…+80°C |
| Max. pressure | 100 bar |
| Protection degree | IP65 |
| Vibrations | IEC 68-2-6 (4g) |
| Mechanical specifications | |
| Thread connections | 3/4” NPT & 1″ BSP |
| Material – liquid parts | AISI 304 / PTFE |
| Material – electronic parts | Coated aluminium |
| House type | Front |
| Approvals | |
| EMC test | EN 61000-2 |
| Indication | |
| Bargraph indication | Red LED |
| Configurations | |
| Configuration | Push button |
| Power supply | |
|---|---|
| Voltage | 24 AC/DC + 10% |
| Max. possible resistance | 500 ohm |
| Plug connection | DIN 43650 – 4 pins |
| Output | |
| Analog output | 4-20 mA |
| Environmental conditions | |
| Ambient temperature | -30…+50°C |
| Refrigerant temperature | -60…+80°C |
| Max. pressure | 100 bar |
| Protection degree | IP65 |
| Vibrations | IEC 68-2-6 (4g) |
| Mechanical specifications | |
| Thread connections | 3/4” NPT & 1″ BSP |
| Material – liquid parts | AISI 304 / PTFE |
| Material – electronic parts | Coated aluminium |
| House type | Front |
| Approvals | |
| EMC test | EN 61000-2 |
| Indication | |
| Bargraph indication | Red LED |
| Configurations | |
| Configuration | Push button |
Inquiry