HBLT-Flex Refrigerant flex sensor

HBLT-flex is a capacitive sensor for level measurement of HFC/HFO/CO2HBLT-flex is a capacitive sensor for level measurement of HFC/HFO/CO2refrigerant in industrial refrigeration systems.

The sensor has an output signal of 4-20 mA, which is proportional with 0 and 100%. Its output signal is 4 mA for an empty container and 20 mA for a full container. HBLT-flex can be adjusted in length to the current application. The sensor element consists of a 2mm steel wire as well as a Teflon tube. Both parts are provided with a length of 4 m and can be shortened with diagonal cutters or other pliers. HBLT-flex can be used in connection with the HBLT-C1 controller for controlling pumps, etc., or it can be configured to directly control a valve without the need for another controller.

Product features:

Flexible sensor wire, which is adjustable to a length of 0 to 1400 mm with a jump of 50 mm.
Sturdy and reliable design with a standard 4-20 mA output signal.
Designed for the refrigeration industry – max. pressure up to 100 bar.
Split design which makes the sensor easy to install and service. The electronic part can easily be separated from the mechanical part by loosening the threaded union.
Simple calibration for the specified length.
Can be used in compact systems where installation height is low.  
Can be used for marine applications, since measurement is not affected by contact with the metal surface of the overflow pipe.

 


Power supply
Voltage 24 AC/DC + 10%
Max. possible resistance 500 ohm
Max consumption 50 mA
Plug connection DIN 0627 – 5 pins
Output
Analog output  4-20 mA, 1 A
Transsistor output – alarm PNP, 1 A
Contact function – alarm NO/NC (Programmable)
Environmental conditions
Ambient temperature -30…+50°C
Refrigerant temperature -60…+60°C
Max. pressure 100 bar
Protection degree IP65
Vibrations IEC 68-2-6 (4g)
Mechanical specifications
Thread connections 3/4” NPT 
Adapter – 3/4″ NPT / 1″ BSPP (option) HBS/ADAP/8/2
Size Se dimensional drawing
Material – liquid parts AISI 304 / PTFE
Material – electronic parts Plast
House type Angle
Approvals
EMC-Emission EN 61000-3-2
EMC-Immunity EN 61000-4-2
Cable
HBxC-M12/5  5 m – 5 wire
Indication
LED indication Green, yellow & Red LED
Configurations
Configuration PC tool

Power supply
Voltage 24 AC/DC + 10%
Max. possible resistance 500 ohm
Max consumption 50 mA
Plug connection DIN 0627 – 5 pins
Output
Analog output  4-20 mA, 1 A
Transsistor output – alarm PNP, 1 A
Contact function – alarm NO/NC (Programmable)
Environmental conditions
Ambient temperature -30…+50°C
Refrigerant temperature -60…+60°C
Max. pressure 100 bar
Protection degree IP65
Vibrations IEC 68-2-6 (4g)
Mechanical specifications
Thread connections 3/4” NPT 
Adapter – 3/4″ NPT / 1″ BSPP (option) HBS/ADAP/8/2
Size Se dimensional drawing
Material – liquid parts AISI 304 / PTFE
Material – electronic parts Plast
House type Angle
Approvals
EMC-Emission EN 61000-3-2
EMC-Immunity EN 61000-4-2
Cable
HBxC-M12/5  5 m – 5 wire
Indication
LED indication Green, yellow & Red LED
Configurations
Configuration PC tool

Inquiry

Niezwłocznie po wpłynięciu do nas zapytania zostanie przygotowana dla Państwa oferta wraz ze szczegółową wyceną.